PU Rigid Foam Raw Materials: 50 Ingredients Guide

PU rigid foam raw materials decide insulation performance, fire rating, and cost. This handbook walks through 50 key ingredients across seven families: polyols, isocyanates, catalysts, blowing agents, surfactants, flame retardants, and fillers. Each entry gives hydroxyl value, functionality, NCO content, or blowing agent class where it matters, plus typical use. Four selection rules close the piece.

Rigid polyurethane foam has the lowest thermal conductivity of any organic insulation material. It is the backbone of polyurethane insulation in construction, cold chain, pipe insulation, and water heaters. One formula means many moving parts: change the polyol and you change strength and dimensional stability; change the blowing agent and you change lambda value and environmental class; change the flame retardant and you change the fire rating. Selecting PU rigid foam raw materials starts with the application.

The tables below list the key raw materials in seven groups, copied from the source handbook. Hydroxyl value is in mgKOH/g. Functionality is the average number of reactive sites per molecule. NCO is the isocyanate group content. ODP and GWP mark the environmental profile of blowing agents.

PU Rigid Foam Raw Materials: The Seven Component Families

Each rigid foam formula sits on seven pillars. The table gives the role of each family and its typical place in the recipe.

Component familyWhat it decidesTypical place in recipe
PolyolsStrength, dimensional stability, and the thermal conductivity floorMain resin; polyol count is 100 parts
IsocyanatesCrosslink density, reaction speed, and heat resistanceBlack material; dose indexed to polyol
CatalystsGel-blow balance, cure speed, and demold timeSmall dose, about 0.1 to 3 parts
Blowing agentsCell structure, lambda value, and environmental classPhysical agent or chemical water
SurfactantsCell size, cell opening, and surface defects1 to 2 percent
Flame retardantsFire rating such as B1, and smoke suppressionAdditive or reactive type
Fillers and release agentsCompression strength, cost, and demold integrityOptional

Polyols: The Backbone That Sets Strength and Dimensional Stability

Polyols set strength, dimensional stability, and the lower limit of thermal conductivity. The source lists twelve named polyols below.

#PolyolHydroxyl valueFunctionalityTypical use
014110 type sucrose-based polyether polyolAbout 430 mgKOH/gAbout 4.1General rigid foam backbone; boards, refrigerators, pipe insulation
021056 type glycerol polyether polyolAbout 560 mgKOH/g3All-water systems; spray rigid foam; low cost, fine cells
03835 type sucrose-sorbitol composite polyetherAbout 350 mgKOH/gAbout 5 to 6High dimensional stability rigid foam; structural board, cold chain
04635 type low-hydroxyl-value glycerol polyetherAbout 350 mgKOH/g3Viscosity reduction and flow adjustment; blended with 4110 and 835
05435 type medium-hydroxyl-value general polyether350 to 450 mgKOH/g3 to 4General rigid foam; ordinary insulation and filling foam
06Pentaerythritol-based polyether polyol4High strength structural foam; imitation wood, structural parts, high-density foam
07Sorbitol-based polyether polyolAbout 6High closed-cell rigid foam; refrigerators and freezers; renewable sugar alcohol starter
08Aromatic polyester polyol250 to 350 mgKOH/gFlame resistance and dimensional stability; PIR board component; blended with polyether to cut cost
09Adipic acid-based polyester polyolAdjustable rangeSpecial rigid foam and RIM; strong substrate adhesion
10Phosphorus-containing flame-retardant polyether polyolPhosphorus about 6 to 10 percentPermanent flame retardance without migration; with TCPP cuts additive dose; B1 building insulation
11Grafted polyether polyol (POP)Solids 20 to 45 percentReinforcement; cell opening stability
12PIR system polyolFor high isocyanate index 200 to 400; stable exotherm with excess pMDI; heat resistance 140 degrees Celsius and above

Sucrose-based and sorbitol-based polyols carry high functionality and build dense networks for structural board. Glycerol-based polyols flow better and fit all-water and spray systems. Aromatic polyester polyols bring flame resistance and lower cost, often blended with polyether in PIR board. Reactive phosphorus polyols bond phosphorus into the chain for permanent flame retardance without migration.

Isocyanates: The MDI Side That Builds Crosslinks

Rigid foam almost always uses MDI-series black material. The isocyanate index decides the system type.

#IsocyanateNCO contentFunctionalityTypical use
17Polymeric MDI (pMDI)About 30 to 32 percent2.7 to 3.0Largest isocyanate use; lower vapor pressure than TDI; refrigerators, boards, spray
18High-functionality polymeric MDI3.0 to 3.3Rigid foam reinforcement; continuous board lines; low-temperature construction
19Liquefied modified MDICarbamate or carbodiimide modified; liquid at room temperature; cast rigid and semi-rigid foam
20MDI prepolymer18 to 25 percentLow free MDI; adjustable viscosity; high environmental requirement occasions; low fogging value
21Isocyanurate-modified pMDIPre-built isocyanurate rings; PIR board; better heat resistance and flame retardance

pMDI is the most used isocyanate in rigid foam. Its vapor pressure is far below TDI, so it is safer to handle. High-functionality pMDI cures faster and suits continuous board lines. Liquid modified MDI eases handling of cast systems. MDI prepolymers cut free monomer and fogging. Isocyanurate-modified pMDI is the base of PIR board, with isocyanurate rings pre-built for better heat resistance and flame retardance.

Catalysts: Balancing Gel, Blow, and Trimerization

Hard foam catalysis balances three reactions: gel, blow, and trimerization.

#CatalystTypeMain roleTypical use
22Triethylenediamine (A-33)Tertiary amine; 33 percent in dipropylene glycolGel plus blow balanceClassic workhorse; almost all rigid foam systems
23Dimethylcyclohexylamine (DMCHA)Cycloaliphatic tertiary amineGel-leaningMain gel catalyst; boards and refrigerators; paired with A-33
24Pentamethyldiethylenetriamine (PMDETA)Tertiary amineStrong gelHigh activity, low dose; low temperature and fast demold
25N,N-dimethylbenzylamineTertiary amineGel-leaning, low costTraditional cost-effective catalyst; watch odor and VOC
26Dimethylethanolamine (DMEA)Hydroxyl-containing tertiary amineBlow-leaningImproves cell opening and flow; low-to-mid grade formulas
27TriethanolamineAlkanolaminePost-cure and low-temperature catalysisHelps foam mature and set; flattens reaction curve with strong amines
28Dibutyltin dilaurate (T-12)OrganotinStrong gelExtreme gel efficiency at tiny dose; organic tin regulation trend
29Potassium octoate or potassium isooctanoateAlkali metal saltTrimerization catalystPIR core catalyst; dose tied to isocyanate index
30Quaternary ammonium trimerization catalystQuaternary salt; Dabco TMR seriesTrimerization catalystMore controllable than potassium salts; longer milk-white stage; high-end PIR

TEDA A-33 is the classic workhorse, promoting both gel and blow. DMCHA and PMDETA lean toward gel and suit fast demold. DMEA leans toward blow and opens cells. Triethanolamine gives mild late-stage catalysis that flattens the reaction curve. T-12 organotin delivers extreme gel efficiency at tiny doses, though organic tin faces regulation pressure. Potassium salts and quaternary ammonium salts drive trimerization in PIR systems; quaternary salts allow a longer milk-white stage for better mold filling.

Blowing Agents: From HCFC-141b to HFO-1233zd(E)

Blowing agents decide lambda value and environmental grade. The industry is in the fourth-generation transition.

#Blowing agentTypeEnvironmental markTypical use
31HCFC-141bHydrochlorofluorocarbonODP above 0; phaseout transitionExisting equipment transition; new projects should choose alternatives
32CyclopentaneHydrocarbonODP 0; GWP about 11Refrigerator and freezer mainstream; explosion-proof design needed
33n-Pentane or isopentaneHydrocarbonLower boiling point; higher foaming efficiencyBlended with cyclopentane; boards and spray
34HFC-245faHydrofluorocarbonODP 0; GWP about 1030Third-generation agent; non-flammable; being replaced by HFO
35HFC-365mfcHydrofluorocarbonOften blended with HFC-227ea for flame retardanceEurope market; GWP phase-down pressure
36HFO-1233zd(E)Hydrofluorolefin fourth generationGWP about 1; non-flammableNear-zero GWP; refrigeration and high-end building materials
37WaterChemical blowing with CO2Zero ODP and GWP; lowest costHigh lambda and embrittlement risk; usually blended in semi-water systems

Cyclopentane is the mainstream agent for refrigerators and freezers, with mature equipment but flammability that needs explosion-proof design. n-Pentane and isopentane boil lower and foam more efficiently, often blended with cyclopentane. HFC-245fa and HFC-365mfc are third-generation agents being replaced by HFO because of high GWP. HFO-1233zd(E) is near-zero GWP, non-flammable, and already scaled in refrigeration and high-end building materials. Water gives zero ODP and GWP at the lowest cost, but CO2 conducts heat well and embrittles foam, so it is usually blended with a physical agent in semi-water systems.

New PU rigid foam raw materials designs should start from pentane or HFO to avoid forced reformulation after HCFC-141b phaseout.

Surfactants: The One to Two Percent Additive That Decides Cell Quality

Surfactants are polyether-modified organosilicones used at 1 to 2 percent, yet they decide cell quality.

#SurfactantFeatureTypical use
38General rigid foam polyether-modified siliconeOrganosilicone surfactant; for example AK8805 typeEmulsifies blowing agent, stabilizes cells, cuts surface tension across most systems
39Full-water system siliconeWater resistance; CO2 emulsificationAll-water spray formulas; helps CO2 nucleate evenly, prevents coarse cells and collapse
40Spray rigid foam siliconeLow-temperature flow plus fast cureBalances substrate wetting and cell stability; prevents sagging and pinholes in winter
41PIR high closed-cell siliconeHigh index tolerance; high heat toleranceSurvives high isocyanate index and high exotherm without brittleness
42High-stability board siliconeWide process windowContinuous board line high-speed production; fewer scrap boards

General silicone emulsifies the blowing agent, stabilizes cells, and cuts surface tension across most systems. Full-water silicone helps CO2 nucleate evenly and prevents coarse cells and collapse in all-water spray formulas. Spray silicone balances substrate wetting and cell stability, preventing sag and pinholes in winter. PIR silicone survives high isocyanate index and high exotherm without brittleness. Board silicone gives a wide process window for continuous lines.

Flame Retardants: Additive and Reactive Phosphorus Systems

Building insulation makes flame retardants the third-largest rigid foam component.

#Flame retardantTypePhosphorus contentTypical use
43Tris(2-chloro-1-methylethyl) phosphate (TCPP)Additive halogenated phosphateAbout 9.5 percentLargest flame retardant use; B1 formulas typically 8 to 15 percent
44Triethyl phosphate (TEP)Additive phosphate; halogen-freeHalogen-banned scenarios; mild odor; higher volatility
45Dimethyl methylphosphonate (DMMP)PhosphonateAbout 25 percentHigh efficiency, lower total dose; doubles as viscosity reducer; watch volatility
46Diethyl hypophosphite (DEEP type)Hypophosphite esterGood hydrolysis resistance; high-end and export products; higher cost than TCPP
47MelamineNitrogen type; sublimation endothermic plus charringP-N synergism with phosphorus; good smoke suppression
48Expandable graphite (EG)Physical intumescent; 80 to 300 mesh commonInsulating char layer when heated; DIN 4102 B1 route; 8 to 15 percent

TCPP is the most used additive flame retardant, with low viscosity and good polyol compatibility. B1 grade formulas typically use 8 to 15 percent TCPP, but halogen controversy and migration are concerns. TEP is halogen-free with mild odor but higher volatility. DMMP packs about 25 percent phosphorus for high efficiency and lower total dose, though it also volatilizes. DEEP hypophosphite esters resist hydrolysis better and suit high-end and export products at higher cost. Melamine gives P-N synergism with phosphorus and good smoke suppression. Expandable graphite forms an insulating char layer when heated and is a main route to grades such as DIN 4102 B1.

Mainstream cost-performance practice pairs an additive flame retardant with a reactive phosphorus polyol. Piling only TCPP will not reach high fire ratings.

Fillers and Mold Release Agents

#AdditiveTypeAddition levelTypical use
49Glass fiber or wollastonite reinforcement fillerInorganic fiber filler5 to 20 percentStructural board and imitation wood; raises compression strength and dimensional stability; raises viscosity and equipment wear
50Rigid foam mold release agentSilicone, wax, or water emulsionMolded foam such as refrigerator liners, imitation wood, and pipe shells; decides demold integrity, surface quality, and topcoat adhesion; water-based is the green trend

Glass fiber and wollastonite raise compression strength and dimensional stability while cutting thermal expansion, at the cost of higher viscosity and equipment wear. Mold release agents are a must for molded rigid foam such as refrigerator liners, imitation wood, and pipe shells; they decide demold integrity, surface quality, and topcoat adhesion.

Limitations

The source handbook introduces this section as 50 materials across seven families but names 46 items in the tables; treat the count as approximate. Blowing agent rules reflect phase-down schedules such as the Kigali Amendment and may differ by region. Hydroxyl values, functionality, NCO content, ODP, and GWP are typical ranges from the handbook, not product specifications; confirm with supplier datasheets before scaling.

Bottom Line

PU rigid foam raw materials work as a system, not a shopping list. Pick the polyol for the mechanics you need, the MDI grade for cure speed, the blowing agent for lambda and environmental rules, and the flame retardant for fire rating. Match PU rigid foam raw materials to the application, and validate with full fire test reports before you scale.

FAQ

What are PU rigid foam raw materials

They are the seven ingredient families that make a rigid polyurethane foam formula: polyols, isocyanates, catalysts, blowing agents, surfactants, flame retardants, and fillers or release agents. Polyols build the polymer backbone, isocyanates crosslink it, and blowing agents open the cells. Catalysts tune the reaction speed, surfactants shape the cells, flame retardants set the fire rating, and fillers or release agents add strength or ease demolding. The choice of each family moves insulation performance, fire safety, and cost at the same time.

Which polyol is the default backbone for rigid foam

The 4110 type sucrose-based polyether polyol is the default base stock in many board, refrigerator, and pipe insulation formulas. It has a hydroxyl value of about 430 mgKOH/g and functionality of about 4.1, giving high crosslink density and balanced strength with dimensional stability. Glycerol-based polyols such as 1056 suit all-water and spray systems instead. Choose sorbitol-based or sucrose-sorbitol polyols when high dimensional stability and compression strength matter most.

Why does rigid foam use pMDI instead of TDI

Rigid foam almost always uses MDI-series black material because pMDI vapor pressure is far below TDI, which makes it safer to handle in factories. pMDI also offers a wide formulation window when combined with polyols, and it fits refrigerators, boards, and spray foam. High-functionality pMDI cures faster for continuous board lines, while liquid modified MDI and MDI prepolymers solve handling, free monomer, and fogging issues in specific processes.

What blowing agent should a new rigid foam formula use

Design new formulas around pentane or HFO. Cyclopentane is the mainstream agent for refrigerators and freezers, with mature equipment but flammability that needs explosion-proof design. n-Pentane and isopentane boil lower and can be blended with cyclopentane to optimize cell structure. HFO-1233zd(E) is near-zero GWP, non-flammable, and already scaled in refrigeration and high-end building materials. Avoid HCFC-141b for new projects because it is being phased down under the Kigali Amendment.

What is the difference between water blowing and pentane blowing

Water is a chemical blowing agent: it reacts with NCO to generate CO2, at the lowest cost with zero ODP and GWP. But CO2 conducts heat well and raises embrittlement risk, so water is usually blended with a physical blowing agent in semi-water systems. Pentane is a physical blowing agent with moderate lambda and proven cold chain equipment. Pentane needs explosion-proof design because it is flammable, while water adds no flammability risk but may need help with cell size and strength.

Which catalyst balances gel and blow in rigid foam

TEDA, known as A-33 and usually supplied as a 33 percent solution in dipropylene glycol, is the classic rigid foam catalyst that promotes both gel and blow. It has broad compatibility and appears in almost every rigid foam system formulation. DMCHA and PMDETA lean toward gel for fast demold, while DMEA leans toward blow and improves cell opening. T-12 organotin delivers extreme gel efficiency at tiny doses, but watch the regulatory trend on organic tin. Potassium and quaternary ammonium salts are reserved for trimerization in PIR systems.

What is T-12 and why is it under regulation pressure

T-12 is dibutyltin dilaurate, an organotin catalyst with extremely high gel efficiency in rigid foam. A tiny dose speeds up gelation a lot, so formulators use it to tune the gel-blow balance. The reason for regulation pressure is the broader restriction trend on organotin compounds over health and environment concerns. Formulators facing limits often shift to amine catalysts or adjust the catalyst blend instead.

How much TCPP is used in B1 grade rigid foam

TCPP is the most used additive flame retardant in rigid foam, with low viscosity and good compatibility with polyols. B1 grade formulas typically use 8 to 15 percent TCPP. The caveat is the halogen controversy and the migration risk of additive flame retardants. For better results, formulators combine additive TCPP with reactive phosphorus polyols, which bond phosphorus into the chain and do not migrate or exude.

What makes PIR boards more heat resistant than PUR

PIR boards use a high isocyanate index, usually 200 to 400, with excess pMDI and trimerization catalysts such as potassium salts or quaternary ammonium salts. The reaction pre-builds isocyanurate rings into the polymer network, which raises heat resistance to 140 degrees Celsius and above and improves flame retardance. PUR systems use lower indexes and do not build the same isocyanurate content, so PIR suits stricter fire standards and higher temperature service.

Do flame retardants affect foam cell structure

Yes. Flame retardant loading changes viscosity, cell nucleation, and foam stability, so high doses can coarsen cells or promote collapse. Expandable graphite, for example, needs care at the cell interface because its particles sit between polymer and cell wall. Melamine powder also needs good dispersion to avoid cell defects. The usual fix is to match the surfactant system to the flame retardant package and keep the loading inside the proven window.

Can expandable graphite replace TCPP

Not one for one. Expandable graphite works by expanding into an insulating char layer when heated, while TCPP acts in the condensed and gas phases as a phosphorus flame retardant. Expandable graphite is halogen-free, suppresses smoke, and reaches grades such as DIN 4102 B1 at 8 to 15 percent loading, but it must solve the cell-interface problem. Formulators more often combine expandable graphite or melamine with TCPP to get P-N synergism and better smoke suppression than TCPP alone.

What filler raises compression strength of rigid foam

Glass fiber and wollastonite are the two inorganic fillers used for this purpose, typically added at 5 to 20 percent. They raise compression strength and dimensional stability while lowering thermal expansion, which suits structural board and imitation wood products. The tradeoff is higher viscosity and more equipment wear. Mold release agents are a separate additive family that decides demold integrity and surface quality for molded parts such as refrigerator liners and pipe shells.